Author |
Message |
Gmartin3
Joined: Oct 19, 2021 Posts: 40
|
Posted: Feb 2, 2023 5:00 PM Post subject: LSL Acquisition |
|
I am working with someone who has a BrainMaster Discovery. He wants to use the lsl layer to send data to BioEra. I looked at the LSL Element In BioEra. As far as I can tell it is limited to 4 inputs. Is there a solution in BioEra that would allow for accessing more data streams With the LSL element?
Thanks
George |
|
 |
jarek
Joined: Oct 22, 2007 Posts: 991
|
Posted: Feb 2, 2023 5:06 PM Post subject: |
|
The LSLAcquisition element can have any number of outputs. That number is determined by the LSL server (it is automatically detected when connectivity is established).
Please note - LSLAcquisition is only a client. It can't act as LSL server. I don't know anything Discovery and its lsl layer, but it must be a server in order to connect it to BioEra. |
|
 |
Gmartin3
Joined: Oct 19, 2021 Posts: 40
|
Posted: Feb 2, 2023 5:34 PM Post subject: |
|
Ok. I created a design with the LSL acquisition element last year with the nexus amp.
I will work with the client to see about this. I have little to no knowledge about OpenVibe |
|
 |
jarek
Joined: Oct 22, 2007 Posts: 991
|
Posted: Feb 2, 2023 6:37 PM Post subject: |
|
I never used OpenVibe for anything else, but the testing with LSL worked just fine.
It may be best to test BioEra with OpenVibe's LSL before trying any other LSL software. |
|